2-Speed 6" Inductor® In-Line Duct Fan™

  • 2-Speed Inductor® In-Line Duct Fan™ DB306

DB306

2-Speed 6" Inductor® In-Line Duct Fan™

160/180

30 W

ETL® Listed

1 year

6"

Y


INSTALLATION INSTRUCTIONS FOR IN-LINE DUCT FANSTM

READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS

WARNING - For General Ventilating Use Only. Do Not Use to Exhaust Hazardous or Explosive Materials and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

All electrical connections to this fan must be made in an approved type junction box. This junction box must be permanently attached to the fan at the point where the motor wires exit the metal duct pipe. The junction box must be reliably mounted to prevent it from shifting or rotating. The junction box can be attached with 2 or more sheet metal screws, rivets or machine screws with a nut and lock washer. Power to the fan must be supplied following all applicable building and electrical codes.

Before Servicing Or Cleaning Unit, Switch Power Off At Service Panel And Lock Service Panel To Prevent Power From Being Switched On Accidentally. When The Service Disconnecting Means Cannot Be Locked, Securely Fasten A Prominent Warning Device, Such As A Tag To The Service Panel.

Suncourt Inc. does not provide electrical connection information.
For your safety and protection follow all instructions and adhere to applicable building and electrical codes.

EXPOSURE TO AIRFLOW TEMPERATURES EXCEEDING 140°F WILL PERMANENTLY DESTROY THE ELECTRIC MOTOR, VOIDING THE WARRANTY

NEVER EXPOSE YOUR IN-LINE DUCT FANTM TO TEMPERATURES OVER 140°F (60°C)

IMPORTANT WARNING

Due to the power of a booster fan, adequate protective measures must be taken to avoid contact with the impeller blades. In-Line Duct FansTM are designed to boost only dry (ambient) heated or cooled airflow in ducts of forced air systems with temperatures between 40°F (4°C) and 140°F (60°C). Suncourt Inc. accepts no responsibility for use of this product in other applications.

ELECTRICAL CONNECTIONS AND WIRING

WARNING - To Reduce The Risk Of Fire, Electrical Shock Or Injury To Persons, Observe The Following:

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

Your In-Line Duct FanTM must be connected to a 110/120 Volt AC, 60Hz fuse or circuit breaker protected power source only in a manner approved by all applicable codes. Never connect your In-Line Duct FanTM to a 240 Volt AC blower motor or other 240 Volt system.

All electrical connections to this fan must be made in an approved junction box. This junction box must be permanently attached to the fan at the point where the motor wires exit the metal duct pipe. The junction box must be reliably mounted to prevent it from shifting or rotating. The junction box can be attached with 2 or more sheet metal screws, rivets or machine screws with a nut and lock washer. Power to the fan must be supplied following all applicable building and electrical codes.

The ground wire (GREEN) must be terminated at the furnace or other suitable ground. The power source must be protected by a fuse or circuit breaker rated at a minimum of 15 amperes.

You may also supply power to your In-Line Duct FanTM using the Suncourt DuctStat® Temperature Sensitive SwitchTM or a standard on/off switch (Purchased Separately).

Operating range is 40°F (4°C) to 140°F (60°C). Exposure to temperatures outside this range voids the warranty.

GENERAL INSTALLATION NOTES

For maximum performance and minimum noise, the best location to install your In-Line Duct FanTM is 6 - 10 feet from the register that needs the boost.
To prevent air leaks use a good quality duct tape to seal seams in the ductwork after installing the In-Line Duct FanTM.
By utilizing tapered reducers you may install larger diameter duct fans in smaller diameter ducts.
Always leave your In-Line Duct FanTM accessible for maintenance, cleaning or repair.

VARIABLE SPEED CONTROL

The In-Line Duct FansTM can be speed controlled using a Suncourt solid state speed control (Purchased Separately). Please visit www.suncourt.com anytime or during business hours you may phone 1-800-999-3267 for information regarding the appropriate speed control for your In-Line Duct FanTM model.

NEVER USE A RHEOSTAT TO CONTROL FAN SPEED.

INSTALLATION INSTRUCTIONS

In-Line Duct FansTM with electrical box attached have the model number extension DBxxx-E.

In-Line Duct FansTM with a power cord attached have the model number extension DBxxx-CRD.

MODEL: DB100

1. Locate the place in the duct where you wish to install the In-Line Duct FanTM.
2. Tape the enclosed template to the duct with the arrow pointing in the direction of the airflow. Cut out the required opening by first drilling a pilot hole and cutting along the dashed line using a jig saw or tin snips.
3. Place the Inductor® In-Line Duct FanTM in the opening, making sure that the fan blade can turn freely. Align the arrow on the unit in the direction of airflow.
4a. Connect the spring through the middle hole provided in the base plate, stretch the spring over the duct and through the middle hole on the other side of the loose plate. Bend the ends of the spring over to secure, providing a snug installation.
4b. Secure the In-Line Duct FanTM in position with the supplied #6 sheet metal screws using the provided holes in the base plate of the unit.
5. Finish the installation by covering the seams in the duct with a good quality aluminum foil duct tape.

MODELS: DB200, DB204

1. Locate the place in the duct where you wish to install the In-Line Duct FanTM. Align arrow
label on unit in direction of airflow.

FLEXIBLE DUCT
2a. Simply cut the flexible duct and slide the In-Line Duct FanTM in place by slipping the cut flexible duct ends over the crimped ends on the In-Line Duct FanTM, making sure the unit is well supported. Complete the installation by securing the In-Line Duct FanTM to the flexible duct with a good quality aluminum foil duct tape or nylon cable ties.

METAL DUCT
2b. Remove a section of the existing ductwork and slide the In-Line Duct FanTM in place by slipping the duct ends over the crimped ends of the unit. Complete the installation by securing the In-Line Duct FanTM to the metal duct with the supplied #6 sheet metal screws spaced evenly around the circumference on each end of the unit.

3. Finish the installation by covering the seams in the duct with a good quality aluminum foil duct tape.

MODELS: DB205, 206, 208, 210, 212, 306, 308, 310, 412, 414, 416, 6GTP

1. Locate the place in the duct where you wish to install the In-Line Duct FanTM. Align arrow label on unit in the direction of the airflow.

FLEXIBLE DUCT
2a. Install connectors onto any uncrimped ends of the unit. Then simply cut the flexible duct and slide the In-Line Duct FanTM in place by slipping the cut flexible duct ends over the connectors or crimped ends on the In-Line Duct FanTM, making sure the unit is well supported. Complete the installation by securing the In-Line Duct FanTM to the flexible duct with a good quality aluminum foil duct tape or nylon cable ties.

METAL DUCT
2b. Install connectors onto any uncrimped ends of the unit, or crimp your existing ductwork. Then simply place the existing duct over the crimped ends of the unit, or the existing crimped ductwork into the unit. Secure the In-Line Duct FanTM to the metal duct with the supplied #6 sheet metal screws spaced evenly around the circumference on each end of the unit.

3. Finish the installation by covering the seams in the duct with a good quality aluminum foil duct tape.

IMPORTANT NOTICE

Single Speed
The motor of your In-Line Duct FanTM may have 1 White and 1 Black wire or 2 Black wires. If you have a motor with a White and Black wire, connect the White motor wire to the White supply wire and the Black motor wire to the Black supply wire. If you have a motor with 2 black wires, connect either of the Black wires to the White supply wire and the other Black wire to the Black supply wire.

Two Speed
Make sure you connect the colored wire as shown in the table below. Failure to connect correctly will destroy the motor. No warranty claim for an incorrectly wired motor will be accepted by Suncourt.

WIRING INSTRUCTIONS FOR IN-LINE DUCT FANSTM WITHOUT POWER CORDS ATTACHED:

DB306: Never connect yellow and red wires together!

DB308 and DB310: Never connect red and black wires together!

Inductor Specs

CLEANING AND MAINTENANCE

Suncourt Inc. recommends that you clean your In-Line Duct FanTM at regular intervals, similar to what is recommended for the fan of your furnace, no less than twice a year. Keep your In-Line Duct FanTM free of lint, dust, and debris. The In-Line Duct FanTM must never be exposed to temperatures over 140°F (60°C).

ONE YEAR LIMITED WARRANTY

Subject to the following limitations, Suncourt® Inc. (manufacturer) warrants that the In-Line Duct FanTM will, for 1 (one) year from date of original retail purchase, but not exceeding 2 (two) years from date of manufacture, remain free from appearance of defects in workmanship or materials. This warranty is subject to the following limitations: (a) manufacturer’s liability is limited to the replacement or repair of the unit, as decided by the manufacturer; (b) a defective unit must be returned, prepaid, with proof of purchase, well packaged to avoid damage in transit; and (c) this warranty does not apply to defects resulting from the alteration, abuse, accidental damage, unauthorized repair, or misuse of the unit. This warranty is given in lieu of all other warranties, guarantees, and conditions on manufacturer’s part, and the manufacturer shall have no tortious or other liability in respect to this In-Line Duct FanTM. Ship unit to Suncourt Inc. only after obtaining a Return Goods Authorization (RGA) number. Returns without this RGA number will not be accepted.

Actual product appearance may differ from illustrations. Suncourt reserves the right to modify any or all of its products features, designs, components and specifications without notice.

SUNCOURT INC.
500 W. SECOND AVENUE • P.O. BOX 40
DURANT, IOWA 52747-0040
1-800-999-FANS (3267)

Copyright 1998-2015 Suncourt Inc. All Rights Reserved

Unit Box Size Packaged Unit Weight Units per Case Case Size Case Weight
W D H lbs.   W D H lbs.
6.25" 6.25" 6.25" 2.25 6 19.25" 13" 7.5" 14.5
No videos for this product category.

NEVER expose your In-Line Duct Fan to airflow temperatures exceeding 140°F(60°C).

  • Make sure all electrical wiring conforms to all applicable codes and standards. If you are not familiar with electrical installations, consult a qualified electrician.
  • Never use an In-Line Duct Fan for dryer venting.
  • Never connect the High and Low speed wires of a 2-speed In-Line Duct Fan together.

Why do I have a room that is always too cold?
Your problem room may be located far from the furnace. Friction in the long duct reduces airflow to the register in that room, thus delivery of heated air. Also, perhaps the room is over an unheated garage or the duct is simply too small (undersized) to get enough heated air to that room. Remember too, when you are delivering heated air to a room, that air has to have a way to get out of that room. Otherwise there will be no air circulation. Does the room have an air return register? If not, is the door of that room kept closed, stopping air circulation?

Why do I have a room that is always too hot ?
The room that you have a cooling problem with may be far away from the central air system. Long duct runs cause reduction in airflow, plus, the cooled air may have heated up before it gets to the problem room. Perhaps the problem run is to a room on the South side of the house, which has a large window, catching a lot of summer heat.
Chances are that your 'hot' rooms are on the second level of your home. You see, cooled air is dense and heavy. It doesn't like to flow upstairs. This is a very common problem, worsened by undersized ductwork and inaccessibility of those ducts.
Particularly for upstairs cooling problems, select the largest fan you can fit and use duct diameter expanders & reducers to adapt to the ducts already in place.

What boost can I expect from an In-Line Duct Fan?
A standard floor or wall register is normally fed by a 6" diameter duct. You would like to boost the airflow from that register because you have a room that is usually cold in the winter or hot in the summer.
The airflow from that register may be as low as 20 or 30 Cubic Feet of air per minute.
Expect this particular example to have double the airflow when an In-Line Duct Fan is installed.

What temperature difference does boosted airflow make?
This is dependent on a host of variables. How well insulated is the room? What heat gain in the summer through a window? How far is the register from the furnace? Is this room over an unheated garage? Etc.
Here is an example:
During the winter heating season, you need a room about 4 °F warmer than it is. To achieve this you will need 11% more airflow out of the register(s) in that room assuming that your furnace runs 60 minutes out of the hour.
If your furnace runs 20 minutes out of the hour on a cold winter day, that is 1/3 of an hour. You will need 3 times the 11% or 33% boost. In most applications, an In-Line Duct Fan will boost up to 80%. Thus, well up to the task of warming up a room.

How loud will the installed fan be?
Suncourt fans are rated between 50-60 dBA. Please visit our Fan Noise & You information page.

How much power does an In-Line Duct Fan use?
Example: The DB206, 6" diameter In-Line Duct Fan is rated at 0.35 Amp.
For a 120 Volt product, that is 0.35 x 120 = 42 Watt.
This is the maximum motor STARTING Watts. Once the fan runs, the actual wattage is 27 Watts. Like a small light bulb. In the Suncourt product specifications section, Inductors are listed by Amperage. As a rule of thumb, running Amperage is about 60% of the listed (start) Amperage.
So, to figure it out: Listed Amperage times Voltage (120 Volt) equals startup Watts.
Actual running Watts are about 60% of that.

What type of motors are used in Suncourt products?
The electric motors used in Suncourt products are C-Frame two-pole motors, Class B, Thermally Protected, sleeve bearings and synthetic lubricant. The exceptions are the 400 Series In-Line Duct Fans which have 4-pole, Class B, Thermally Protected motors with sleeve bearings and synthetic lubricant.

Can I use a rheostat or fan speed control with an In-Line Duct Fan?
You can not use a rheostat. A rheostat lowers the voltage supplied to the fan motor. This will cause the motor to overheat and theThermal Protector will open, destroying the motor.
A solid-state fan speed control can be used. Suncourt sells two versions of a solid state fan speed controller. The VS100 is a hardwire version that is mounted in your wall similar to a light switch. The VS200 is a plug-in model that plugs into an outlet then the In-Line Duct Fan is plugged into the variable speed switch.

What does Thermally Protected mean?
A thermally Protected motor contains a fuse that will cut off power to the motor should the motor temperature exceed a safe limit. All Suncourt electric motors are Thermally Protected.

What are the fan blades made of?
The 4"-8" In-Line Duct Fan are equipped with Polycarbonate fan blades. (A high strength superior material as used for jet fighter canopies). The 10"-14"In-Line Duct Fans have aluminum fan blades.

How many Inductor fans can I install?
We recommend that you do not install more than 2 In-Line Duct Fans per 8 registers in your air distribution system.
Two boosters will not appreciably affect the airflow to the remaining registers.
If you install more than 2 In-Line Duct Fans per 8 registers, you may be lowering the airflow from a register in some other room in your home, thus creating temperature problems there.

Will an Inductor always double airflow from any register?
No. An In-Line Duct Fan will boost airflow more to a poorly performing register (which is the register needing help) than to a register that already has good airflow. As stated before, a poorly performing register may have double the airflow with an In-Line Duct Fan. A well performing register may have a 30% to 50% percent increase in airflow.

What is the difference between Free Air and Boosted Air?
Free air is the air volume output from a fan, expressed in Cubic Feet per Minute (CFM) when the fan is not connected to any ductwork, pipes, louvers or other items that would interfere with the free flow of air from the fan.
Boosted Air is the maximum airflow that can be passed through an In-Line Duct Fan in CFM before this fan, installed in a duct, becomes a hindrance to airflow rather than boosting an existing airflow.
Depending on the specifics of the electric motor and fan blade combination, Boosted Air can be between 50% to 100% greater than Free Air.

Can I "over boost" a register?
Suncourt In-Line Duct Fans are designed to provide progressive boost. This means that the airflow is proportionally boosted to the need of a particular register. Our booster fans are designed to run at a low RPM in free air. At this RPM, the fan motor runs below the peak torque that can be generated by the motor. Depending on the air blown into the intake side of the In-Line Duct Fan, the RPM will adjust itself as needed to provide boost and will operate at or near peak torque of the electric motor.

In what type of duct can I install an In-Line Duct Fan?
In-Line Duct Fans are suitable for installation in metal, flexible or high density pressed fiberglass ducts. The In-Line Duct Fan can be secured to the duct with screws or a good quality duct tape.

Can I build-in an In-Line Duct Fan, i.e. drywall or panel over it?
No. The In-Line Duct Fan must always remain accessible for service, cleaning or repair.

Can I use the In-Line Duct Fan to vent outside air?
The In-Line Duct Fan has to be protected from rain and excessive moisture.

What is the lowest airflow temperature for an In-Line Duct Fan?
To maintain good oiling of the motor bearings, we recommend a minimum temperature of 40°F (4°C).

What do I typically need for electrical installation?
You will need a small electrical box to mount on the In-Line Duct Fan.
We recommend #8 self-piercing or self-drilling sheet metal screws, ½" to 5/8" long. Do not pre-drill the electrical box mounting holes. Be sure these screws do not touch the fan blade or the electric motor.
For this box you will need a power supply strain relief to mount in a "knockout" in the electrical box.
Choose the power cable to conform to the applicable codes and standards. The staff at your favorite Home Center can recommend these materials to you.

Where do I get power from for the In-Line Duct Fan?
Here you have a number of options.
The easiest way to power your In-Line Duct Fan for automatic ON/OFF operation with both your furnace and air conditioner is to use the Suncourt DuctStat. Please view the DuctStat section of these FAQ's.
You may power the In-Line Duct Fan via a standard wall switch for manual ON/OFF operation. Running an In-Line Duct Fan continuously will not appreciably affect the life of the fan.
The next best is to connect to the wiring of your furnace. You must connect to the wire that provides power to your furnace blower. Consult the furnace wiring diagram, usually located on the inside of the panel covering the main furnace blower. Again make sure that all wiring conforms to all applicable standards and codes.
Also check that your furnace blower motor has a 110-120 Volt AC motor. Some larger furnaces have 220-240 Volt AC motors. Some of the newest high-end furnaces have DC motors. Do not connect the In-Line Duct Fan to either the 220-240 Volt AC or the DC type.
.
Because of the numerous variations in furnace wiring, Suncourt cannot advise you on the hookup.

Can I wire my two-speed In-Line Duct Fan to run on High or Low speed?
Yes, but first this warning. NEVER connect the High and Low speed wires together.
The motor wiring will burn out in a matter of seconds, permanently destroying the unit. Wire to operate either on High speed or Low speed. Never both.
You may use a Single Pole, Double Throw "ON-OFF-ON" toggle, rocker or other switch to wire for High or Low speed operation. This switch must be rated for 125 Volt AC, 10 Amp minimum. Now you can switch your 2-speed Inductor from High to Low speed and have a center OFF position. Connect the supply power to the C (common) terminal, the High speed wire from the motor to the terminal marked 1 and the Low speed wire from the motor to the terminal marked 2. Make sure that the wiring and enclosure for this switch conform to all applicable standards and codes.

Is the In-Line Duct Fan safe?
The In-Line Duct Fans have been rigorously tested to the Standards of Underwriters Laboratories Inc. and are listed by Intertech Testing, ETL® (C/US). All Inductors have Thermally Protected electric motors.